Do I need planning permission for a loft conversion?
Checked against Schedule 2, Part 1, Classes B and C of the General Permitted Development Order 2015.
England, houses only. Scotland, Wales and Northern Ireland run separate planning systems with different limits. Permitted development rights for roof extensions do not apply to flats or maisonettes at all. This is an independent guide, not a government service , the official rules are published free on GOV.UK.
Your volume allowance is 50m³
Everything added to the original roof space, earlier work included
Earlier additions eat the same allowance
Help me estimate the volume
For a flat-roofed box dormer, multiply the three outside dimensions. Measure externally, in metres , the thickness of the walls and roof counts. This writes into the field above.
Enter all three dimensions.
Hip-to-gable and mansard work does not estimate well this way, because the roof shape changes rather than a box being added. Those need a measured drawing.
,
,
This reports what the published rules say about the answers you gave. It is not a decision. Only your local planning authority can determine your project, and this site has no connection to any council or government body.
Why permitted development does not cover this
Conditions it must still satisfy
Find these out before you rely on this
This tool reads the published rules against your answers. It is not a formal determination. Only your local planning authority can confirm your project, and a lawful development certificate is how you get that in writing , the fee is half the planning application fee, so £274 against the current £548 householder fee in England. Buyers’ solicitors increasingly ask for one.
Which rules this uses
Class B covers roof enlargements: dormers, hip-to-gable and mansard work. The volume added to the original roof space must not exceed 40m³ for a terrace house or 50m³ for any other house, counting every earlier roof addition. Nothing may exceed the height of the highest part of the existing roof, nothing may extend beyond the roof plane of a principal elevation fronting a highway, and no verandas, balconies or raised platforms are allowed. Class B does not apply at all on article 2(3) land , conservation areas, National Parks, AONBs, the Broads and World Heritage Sites.
Class C covers alterations that do not enlarge the house, which is what a rooflight conversion is. There is no volume limit. The alteration must not protrude more than 0.15m beyond the plane of the original roof slope, and must not sit higher than the highest part of the original roof. Class C carries no article 2(3) exclusion, which is why rooflight conversions are often still possible in conservation areas when a dormer is not.
Under Class B the original eaves must be kept or reinstated except on a hip-to-gable, the enlargement should sit at least 0.2m back from the eaves so far as practicable, nothing may extend beyond the outside face of an original external wall, and materials must be of similar appearance. Side-elevation windows must be obscure-glazed and non-opening below 1.7m from the floor.
An end-of-terrace house counts as a terrace house for the volume limit, so the allowance is 40m³, not 50m³.
Source: Permitted development rights for householders: technical guidance, updated 10 September 2019, reflecting Schedule 2, Part 1 of the GPDO 2015. Checked against the live page on 18 November 2026. Fees from the England fee schedule effective 1 April 2026; a rise to £575 is proposed for applications from 8 December 2026 but was not confirmed when this page was written.
Where this page states a statutory limit or test, it uses the wording of the legislation, because a loose paraphrase of a legal test is a wrong one. Everything else , the explanations, the ordering, the warnings and this tool’s logic , is our own work. Contains public sector information licensed under the Open Government Licence v3.0. © Crown copyright 2019.